Chapter I · Stan Schneider

Frontier Shield

Can the discharge in a sealed argon cassette provide a measurable benefit without increasing local load?

Concept cutaway of a laboratory cassette with a sealed argon volume, flush pickup and drive coil.
Sealed argon cassetteThe laboratory concept shows the sealed argon volume, flush pickup and drive coil.Open full-size research figure

Overview

Frontier Shield studies a sealed argon cassette for spacecraft and surface systems. The proposed experiment asks what changes when the internal discharge is added to the same driven assembly. Ion load, absorbed dose and dust transport are three separate outcomes.

We constructed cases in which a real change and instrument pickup produce identical readings, then worked out what an independent observation would have to resolve. The later calculations add a joint requirement for total benefit and local load, and show how thermal state, spatial coverage and live calibration can change that decision.

Research status. The evidence consists of analytical results, simulated comparisons and a reanalysis of published particle-monitor data. The Frontier Shield cassette has completed zero physical runs. Protection, engineering readiness and scientific priority remain open.

Concept rendering of the FS-82 cassette on a test stand with callouts for the RF coil, argon gap, frame-mounted sensors and an independent sensor.
FS-82 test fixture conceptThe 3D illustration shows the sealed argon gap, RF coil, frame-mounted sensors and independent reference sensor.Open full-size research figure

Comparison with prior work

We found no direct counterpart in the reviewed studies to the proposed paired test on one sealed argon cassette. It compares the driven assembly with and without a discharge, then evaluates overall benefit and local load for particle fluence, absorbed dose and dust transport. The comparisons below identify exactly which question carries over from each earlier experiment. Scientific priority remains open.

When a changed detector reading has two causes

PUBLISHED STUDY

Erik Marten Klein, Patric Seefeldt, Maciej Sznajder & Thomas Renger · 2023

Klein and colleagues ran proton and vacuum-ultraviolet sources together in the DLR vacuum facility. The Faraday-cup current changed. They identified ionization of the VUV source gas by the proton beam as the likely cause. [1]

Scope. The experiment establishes how two active sources in that facility can change the current readout. It used a shared irradiation chamber.

FRONTIER SHIELD

Extension and result

We took the same attribution question into a paired test of a sealed cassette. The calculation includes a driven control with no discharge and pickup that appears only in the discharge state.

Established in the model. A real response and discharge-correlated pickup produce exactly the same active and control-subtracted readings in the constructed pair. An independently coupled channel distinguishes the specified cases at 48 s in the modeled setting.

A physical change of two and pickup of two each move the standard reading from 10 to 12. An independent channel reads two versus zero. In the center benchmark the change was unresolved at 24 seconds and was identified in all 128 trials per true-effect case at 48 seconds, with zero detections for pickup alone.
A real change and electrical pickup can share a readoutThe top row uses the worked example in arbitrary units. The bottom row summarizes the separate synthetic timing benchmark at its central setting. The independent path identified the stipulated true effects at 48 s and rejected pickup alone in that setting.Open full-size research figure

Testable hypothesis. Under live exposure, an independently calibrated fluence measurement should recover a real change and reject an equal electrical pickup. Test it with hidden, physically referenced signal and pickup challenges.

Recalculate the example

Use a reduced example of the same observation equation. Set the common control reading to 10 and the change to 2 in arbitrary readout units. The independent channel is defined here to respond one for one to the physical change and zero to pickup.

  1. Physical change: (10 + 2 + 0) − 10 = 2
  2. Pickup alone: (10 + 0 + 2) − 10 = 2
  3. Independent channel: 2 versus 0

Expected result. Both standard records agree and the independent channel resolves the cause under the stated coupling. The full synthetic test verifies 1,280 paired equalities.

What the walls and pressure can reveal about argon

PUBLISHED STUDY

J. M. de Regt, R. D. Tas, J. A. M. van der Mullen & D. C. Schram · 1996

De Regt and colleagues characterized a closed inductively coupled argon discharge for lighting. Their diagnostics included emission, Thomson scattering and absorption. They measured electron properties, heavy-particle temperature and wall temperature. [14]

Scope. The plasma occupied 2 cm³ and the fill pressure ranged from 10 to 100 mbar. The measurements characterize the lamp across different operating conditions.

FRONTIER SHIELD

Extension and result

We shifted the question to inference about the neutral gas in a sealed planar gap. We retained both wall temperatures, total inventory and the common pressure, then asked if those quantities determine the interior temperature.

Established in the model. Two mirrored profiles meet those constraints exactly in the continuum model. They give 345 K and 363 K at a quarter of the gap. The pressure is common because the profiles have the same reciprocal-temperature integral.

Two exact modeled temperature profiles share wall temperatures of 300 kelvin and a common pressure. At a quarter of the gap the two values are 345 and 363 kelvin.
The same wall and pressure readings allow different gas profilesThe two modeled profiles mirror one another. They share the same wall readings, inventory and pressure, with an 18 K difference at a quarter of the gap.Open full-size research figure

Testable hypothesis. With matched wall readings and pressure in the two cassette states, a spatially resolved neutral-gas measurement can still detect a nonzero difference. Compare independently calibrated off-center readings and check that the measurement itself leaves the thermal state unchanged.

Recalculate the example

Let u be fractional depth. Both walls are 300 K. Use the two profiles with a = 0.24 and b = ±0.08 at fixed inventory.

  1. g = 4u(1 − u)
  2. T = 300[1 + 0.24g + b·g(2u − 1)]
  3. At u = 0.25: g = 0.75, 2u − 1 = −0.5

Expected result. T is 345 K with b = +0.08 and 363 K with b = −0.08. At both walls g is zero. Changing the sign of b reflects the profile in u = 0.5.

A spatial dose map changes the decision at a seam

PUBLISHED STUDY

Bernard Gottschalk, Ethan W. Cascio, Juliane Daartz & Miles S. Wagner · 2015

Gottschalk and colleagues measured absolute absorbed dose from a 177 MeV proton pencil beam in water. Depth scans at ten distances from the axis, up to 10 cm, resolved the central beam and surrounding dose. [15]

Scope. The measured reference is a water tank and a single beam. A separate fluence-calibrated ionization chamber served as the beam monitor.

FRONTIER SHIELD

Extension and result

We keep the 177 MeV water-dose question and add two adjacent cassette positions and a separately judged seam. We compare the predicted joint dose when the two single-cassette maps agree in their averages but differ in how their high and low regions line up.

Established in the model. Under a pointwise product model, the same two single-cassette seam means of 1.020 give joint ratios of 1.039175 or 1.041625. These straddle the illustrative 1.040 seam cap. The wider region passes its separate 0.990 cap in both constructed cases.

Both modeled full-region dose ratios are below 0.990. The seam ratios are 1.039175 with opposing peaks and 1.041625 with aligned peaks, against a 1.040 limit.
Alignment changes which case passes the seam limitThe 177 MeV comparison uses constructed cassette response maps and a pointwise product. The two cases pass the full-region limit. The aligned peaks exceed the separate seam limit.Open full-size research figure

Testable hypothesis. With a registered physical dose map, shifting the relative location of the two response peaks could change the seam dose while the full-region verdict stays the same. Compare the joint measurement with the registered product prediction and check beam position, water-equivalent thickness and secondaries separately.

Recalculate the example

Use equal baseline weight for the two halves of the seam. Each single-state map has local ratios 0.985 and 1.055. Keep the first map fixed and reverse the order of the second to change the alignment. For the full region each interior half has weight 0.48 and the seam has combined weight 0.04. The two interior ratios are 0.982 and 1.002 in opposite order in the two maps.

  1. Single-state mean: (0.985 + 1.055) / 2
  2. Opposite peaks: 0.985 × 1.055
  3. Aligned peaks: (0.985² + 1.055²) / 2
  4. Interior contribution: 0.96 × 0.982 × 1.002
  5. Full ratio: interior contribution + 0.04 × seam ratio

Expected result. The single-state mean is 1.020 in both cases. The joint ratios are 1.039175 and 1.041625 at the seam, and 0.98617244 and 0.98627044 in the full region.

A surface can clear while dust returns somewhere else

PUBLISHED STUDY

Charles R. Buhler and colleagues · 2025

The NASA team demonstrated electrodynamic removal of lunar regolith on Blue Ghost. The study establishes an active surface-cleaning effect in a lunar demonstration. [4]

Scope. This is a test of the electrodynamic surface technology on the lander. The original report concerns removal from the treated surfaces.

FRONTIER SHIELD

Extension and result

We carry the cleaning question into a paired-cassette model. Alongside net removal, the calculation distinguishes the first side reached by returning dust from later crossings, with the same external cleaning drive in the proposed plasma comparison.

Established in the model. Two synthetic routes preserve the same terminal mass map, return totals and 48 µg of gross crossings per direction. They give 12 µg and 44 µg of opposite-side first returns per direction.

Both synthetic dust tables have 64 micrograms in every row and column and 48 micrograms of gross crossings per direction. Unique first return is 12 versus 44 micrograms per direction.
Dust return can change when the totals agreeThe synthetic records have matching endpoint totals and gross seam traffic. The history of the marked particles distinguishes 12 from 44 µg of first return in each direction.Open full-size research figure

Testable hypothesis. A tagged cohort and an independent view of the first return should distinguish paths that leave the same terminal mass and gross crossing count. Test the tag and its influence on transport before attributing a change to the discharge.

Recalculate the example

Rows are left and right starting cohorts, columns are left and right first-return destinations. Masses are in µg. In the two cases, later loops contribute 36 or 4 µg to gross crossings in each direction.

  1. Case A: [[52, 12], [12, 52]]
  2. Case B: [[20, 44], [44, 20]]
  3. Gross crossings: 12 + 36 = 44 + 4

Expected result. Every row and column totals 64 µg and gross crossings total 48 µg per direction in both cases. The off-diagonal entries, which count opposite-side first returns, differ by 32 µg per direction.

Research updates

Chapter I · Separating the discharge from the measurement

Identifying the plasma effect

Two causes can produce the same record

Exact ambiguity in a specified observation model · synthetic check

Suppose the readout changes only when the discharge is on. A physical effect and electrical pickup that occurs only with the discharge can produce exactly the same record, even after subtracting a driven, discharge-free control.

In a vacuum irradiation facility, Klein and colleagues measured a change in Faraday-cup current when proton and vacuum-ultraviolet sources operated together. That experiment establishes a real example of cross-source interference in a different apparatus. [1]

We constructed paired cases with matched drive-on and control-subtracted readings. The difference in causes is exposed by adding a channel with independently modeled coupling to the endpoint.

Y=S+P

Y is the control-subtracted readout, S is the physical contrast and P is the contribution from pickup present only in the discharge state.

Open question A physical reference must be calibrated in the live exposure and shown to remain independent at the relevant accuracy.

Derivation and checks
Paired equality
All 1,280 synthetic combinations of error draw, command and read time preserved equality between the two records.
Independent channel
At 24 s its contrasts were unresolved. At 48 s it distinguished the specified physical alternatives from pickup alone in the modeled central setting.
  1. Construct equal Y by placing the same change in S or in P.
  2. Use matched error draws to verify equality at each sampled condition.
  3. Compare the second observation, whose response to the two causes was specified separately.

Adding repeats of the original channels preserves the ambiguity in this construction. The two read times describe the model and depend on its assumed response.

The contribution is the explicit counterexample after control subtraction, together with a discriminating observation in the same model.

Matching the generator can leave the cassette unmatched

Exact single-frequency compatibility criterion · illustrative circuit and thermal model

The same generator reading can accompany different conditions near the sample. A load placed away from the coil can reproduce the impedance seen at the source while leaving a difference at the coil terminals.

Argon discharge experiments already separate the power absorbed by plasma from losses in the coil and matching circuit. Frontier Shield applies that distinction to a control that must operate with no discharge. [2]

We derived the condition for simultaneous current and voltage matching at a single reference plane, then compared a source-side load substitute with a control that also tracks heat at the cassette.

|r−1|≤εI+εV|r|

r is the ratio of the two complex impedances at the same reference plane. εᵢ and εᵥ are the relative current and voltage tolerances. The current phasor can be freely selected in the stated model.

Open question Establish that comparable coil current and thermal history can coexist with a reproducible absence of discharge.

Derivation and checks
Electrical overlap
The two chosen impedances require at least 10.72% tolerance on each observable when the tolerances are equal. Exact current matching leaves a 22.61% terminal voltage difference.
Thermal replay
In a separate three-node thermal model, an exact mount match at one instant leaves up to 0.370 K error over the cycle. Two heaters leave a 0.04764 K bound after accounting for the modeled gain error, against a 0.050 K allowance.
  1. Normalize the control current by the discharge current.
  2. Translate the voltage tolerance into a second disk in the same complex-current plane. Disk overlap gives the criterion.
  3. Evaluate the electrical and thermal comparisons at their respective physical locations.

The impedances, heated nodes and gain errors are stipulated inputs. The calculated tolerances are specific to those examples.

The drive-, coil- and sample-side observations qualify different parts of the comparison.

Measuring benefit and local load

A useful shield must pass the local load limit too

Sharp bounds for bounded linear errors · specified decision examples

An average improvement can hide greater exposure at an edge or seam. A fall in charged-hydrogen counts alone also leaves open what happened to neutral hydrogen and where particles first struck the assembly.

Mini-magnetosphere experiments studied an open flowing plasma and magnetic dipole. Lunar dust removal has been demonstrated separately. A prior NIAC concept already considered radiation shielding and dust removal together. Those studies supply relevant mechanisms and comparisons for the distinct sealed-cassette question. [3][4][5][6]

We imposed a minimum total benefit and a separate maximum local load on the same possible physical state. A common nuisance can shift both estimates. We retained that shared variable when checking whether both requirements are jointly feasible.

yj=θj+ajz+ej
bj=εj+|aj|r

θⱼ is the physical contrast, z is a shared nuisance bounded in magnitude by r, and eⱼ is a per-channel error bounded by εⱼ.

Open question Calibrate the joint response and validate the absolute load over the actual boundary of the protected region.

Derivation and checks
Separate passes can conflict
Take measured benefit 0 and local load 1 with unit slopes and no separate readout errors. For z between −2 and +2 the physical values are −z and 1 − z. Benefit ≥1 requires z ≤−1, while load ≤0 requires z ≥1. Each interval is nonempty and their intersection is empty.
Absolute edge load
An incremental limit needs a matched baseline map and a bound for regions outside coverage before it can support a claim about absolute load.
  1. Bound each output by maximizing its signed error over the same nuisance interval.
  2. Intersect the nuisance ranges allowed by benefit and local load.
  3. Test the intersection explicitly instead of combining two independent favorable values.

Shared effects, coverage and units are branch specific. An increment and an absolute load are distinct quantities.

The work adds a scoped decision rule and a counterexample to evaluating the two criteria in isolation.

Aggregate counts can conceal a seam overload

Exact spatial–temporal counterexample · synthetic adjacent-cassette comparisons

Across four adjoining regions and two exposure windows, a change can cancel out of every pairwise projection while creating a local peak. Measurements at specific positions and times are needed to resolve it.

Discrete arrays with identical marginals and the algebra of factorial contrasts are established. Water-phantom studies in an applied field establish a precedent for spatial proton dosimetry. We apply the hidden-mode calculation to the cassette junction and work out the effect of missing observations and instrument drift. [7][8][12]

We derived a hidden signed mode, compared how much of it can be recovered under different nuisance assumptions, and exhibited separate dose and dust examples where nearly identical summaries lead to different decisions.

χ(x,y,t)=xyt

x and y index the four quadrants and t indexes two physical exposure windows. Each index takes values −1 and +1.

Two exposure windows show opposite checkerboards of the signed x times y times t pattern. The signs cancel when any coordinate is summed out, even though a local contrast remains.
A junction pattern that cancels out of the summariesThe exact three-way contrast can hide in all pairwise summaries. The coverage requirement depends on which effects the reference model allows.Open full-size research figure

Open question A seam test requires independent local observations in a common physical window. A sealed-array scale-up remains a separate investigation.

Derivation and checks
Missing observations
For a known baseline and affine nuisance, four suitably placed observations identify the mode. All eight are necessary and sufficient to tolerate an arbitrary single loss. With unrestricted pairwise nuisance the no-loss design already needs all eight.
Dose routing
Two constructed seam cases have the same single-module mean of 1.020. Their joint ratios are 1.039175 and 1.041625, on opposite sides of 1.040, with both wider-region ratios near 0.9862.
Dust return
Identical aggregate endpoints and gross seam traffic conceal 12 versus 44 µg of unique first return in a constructed pair.
  1. Add a multiple of χ to the common reference. Summing over any coordinate removes the perturbation.
  2. Cancel affine nuisance on a complete face and use rank tests for the retained patterns.
  3. Check dose overlap and dust return with separate spatial and temporal records.

The eight-observation recovery claim depends on the nuisance class. An unrestricted instrument term with the same pattern can conceal the physical contrast even on the full cube.

These are design bounds and counterexamples, with no physical seam runs.

The incident spectrum can change behind a steady monitor

Secondary analysis of published spacecraft observations · reference comparison

In September 2017 GOES‑13 observed two hours with nearly the same integral proton intensity above 10 MeV. The fraction of those protons above 60 MeV differed appreciably.

NASA and NOAA supply the proton monitor data through the high-resolution OMNI product. The project calculation uses those records as a check on what a single normalization channel can establish. [9]

We compared 864 five-minute records and selected two one-hour intervals to illustrate the difference. For a detector with fixed nonnegative response in three energy bins, the two normalized readings have a ratio bounded by the smallest and largest of the three bin-fraction ratios.

Ys=∑jKjfsⱼ

f is the fraction in energy band j during interval s, and K is the fixed nonnegative response in that band. The bounding argument holds at fixed angle distribution and geometry.

GOES-13 proton intensity above 10, 30 and 60 MeV from September 10 to 12, 2017. Among protons above 10 MeV, the share above 60 MeV is 10.35 percent in the selected 06:00 UTC hour and 7.25 percent in the 12:00 UTC hour, on September 11.
Nearly equal monitor readings can hide a change in spectrumThe curves use 864 measured five-minute samples from GOES‑13 via NASA SPDF OMNI. The shaded intervals are two selected UTC hours in the event. Their mean intensity above 10 MeV differs by about 0.25%.Open full-size research figure

Open question Measure incident energy as well as fluence in a paired dose experiment.

Derivation and checks
Low-threshold monitor
The selected >10 MeV hourly means differ by about 0.25%.
High-energy share
The >60 MeV fraction falls from 10.35% to 7.25% in the selected pair.
  1. Verify the five-minute cadence and ordering of the nested intensity channels.
  2. Subtract consecutive thresholds to obtain disjoint bands.
  3. Write the response ratio as a weighted mean of the bin-fraction ratios.

The two hours were selected after examining the series and illustrate a specific event. No capsule or dose measurement is inferred from these satellite records.

This section uses published measurements. The response comparison and the selection of the illustrated intervals are the project analysis.

Qualifying the control and references

Equal wall temperatures can conceal unequal gas profiles

Exact mirrored continuum profiles · fixed planar inventory

The modeled walls and pressure agree, yet the gas temperatures at a quarter of the gap differ by 18 K. A single pressure gauge and matched wall readings can therefore leave different interior thermal states consistent with the record.

Measurements of argon discharges describe transitions and gas heating in other geometries. The example here uses a prescribed continuum heat equation so the ambiguity at fixed wall readings and gas inventory can be constructed explicitly. [2]

We built two mirrored profiles with nonnegative distributed heating, equal pressure and identical total normal gas column. We then bounded what could be achieved by changing the two wall temperatures alone in the fixed-source model.

g(u)=4u(1−u)
T±Tw=1+ag±bg(2u−1)

u is fractional depth. The chart uses wall temperature 300 K, a = 0.24 and b = 0.08.

Open question Test a thermal readout that resolves across the gap and verify that using it does not change the thermal state.

Derivation and checks
At one quarter of the gap
The two profiles give 345 K and 363 K. Each has a 348 K arithmetic mean and both walls are 300 K. The pressure enclosure shared by both is 2.30952–2.31036 Pa, rounded outward.
Wall-only correction
In the specified constant-conductivity model, the best two-wall correction leaves a 12 K interior maximum mismatch for the 48 K odd-mode coefficient.
  1. Reflect u about the midpoint. The even part stays fixed and the odd part changes sign.
  2. At fixed inventory, the reflected profiles have the same integral of reciprocal temperature, hence the same pressure.
  3. With fixed distributed heating, a change of the two wall values adds an affine function. Minimize its remaining difference from the odd profile.

The illustration shows exact profiles of the chosen continuum problem. Rarefaction, surface accommodation and a real heating distribution require independent qualification.

Equal boundary readings and equal full column leave local density and temperature unresolved in the stated model.

A calibration can miss the interaction it needs to bound

Sharp bounds in specified witness geometries · synthetic comparisons

If an instrument responds to two coupled effects, measurements along either axis alone can miss the term that matters when both are present. Repetition also cannot separate alternatives once their worst-case bias intervals overlap.

Factorial experiments and bounded measurement uncertainty are established. We applied those tools to the joint benefit and local-load decision on the same cassette. [6][10]

We propagated a bounded product term through the admissible measurement region and compared one combined reference with two independent references. We also separated errors that shrink with repeats from a systematic overlap that does not.

q(x,y)=ax+by+γxy
G>2d

x and y are normalized nuisance coordinates. G is the separation between alternatives and d is the symmetric systematic error bound in the separate repeated-measurement test.

Modeled fractions of the uncertainty budget for one combined reference and two independent references. The combined dust result is above the limit.
The uncertainty cost of a combined referenceFor each endpoint, one is the entire remaining reserve. The dose model has no feasible single-reference design under its assumptions, so it has no corresponding bar. Values use synthetic inputs.Open full-size research figure

Open question Verify each reference in the live state, including its cross-talk and its influence on the quantity being measured.

Derivation and checks
One reference versus two
The dust example consumes 1.100 of its uncertainty reserve with one combined reference and 0.684 with two independent references. Under the stated dose model one combined reference is insufficient even without readout noise.
A joint challenge
The mixed coefficient is invisible along the separate axes. In the calculated example, a withheld simultaneous change tests the assumption that the estimated interaction applies in the decision region.
  1. Evaluate the weighted absolute error over the constrained region for both outcomes.
  2. Inspect quadratic edge extrema as well as vertices when the mixed term is present.
  3. Ask whether total bias can shift each of two candidate outcomes onto the same observed record.

The comparisons use branch-specific bounds. They do not supply measured precision requirements for an unqualified instrument.

The calculation identifies when a simpler reference or a longer repeat series leaves the engineering decision unresolved.

A finite sensor can hide a peak between readings

Bounds for positive averaging kernels · synthetic spatial comparisons

A sensor averages over an area or volume. Its center and width enter the uncertainty bound. Treating it as an exact point can make a calibration appear sufficient even when the spatial error budget is exceeded.

Laser-scattering measurements in an argon plasma use finite spatial resolution. An independent response and position calibration is needed to turn a neutral-density observation into a constraint on the temperature comparison here. [13]

We bounded an interior peak under a curvature bound and uncertain measurement centers. For positive averaging kernels, the error contains both the spread within each sensor and the squared separation of their centers.

E≤ε+Mh28

In this point-sensor limit, h is the largest spacing, M bounds the magnitude of the second derivative, and ε bounds each reading error.

Open question Measure position and footprint and check the between-point bound with a held-out interior challenge.

Derivation and checks
Wind example
Four intervals give a sufficient point-sensor bound of 0.42418 K. Including finite sensing and uncertain registration raises it to 0.51528 K against a 0.500 K target. Five intervals give 0.42359 K under the stated assumptions.
Dust example
For six intervals the upper bound changes from 0.37500 K to 0.42487 K against a 0.400 K target. Seven intervals give 0.38599 K with the stated improved calibration.
  1. Expand about the interpolated location. The known centers cancel the first-order term.
  2. Carry both sensor variances and the center-gap bound into the curvature term.
  3. Check the worst point between the centers.

Signed extraction can evade a bound that uses only positive-kernel moments.

The comparison identifies when finite sampling invalidates an apparent calibration pass.

Matching a few references leaves gaps between them

Exact finite-sampling counterexample · conditional continuous bound

Three known levels can expose curvature in a detector response. A response may also agree at all sampled levels and still bend sharply between them, even when it remains smooth and monotone.

The second divided difference is a weighted average of curvature with a triangular kernel. We use that established identity to decide what a live calibration can bound under explicit regularity and readback assumptions. [6][11]

For a positive affine response, a live zero and a second level bound offset and gain. For nonlinear response we derived the uncertainty term for three measured levels and a conditional bound between them. A localized perturbation preserves every finite calibration reading while making the peak curvature arbitrarily large.

bD=4eh2

The three calibration levels are spaced by h on either side of their center, and e is the absolute error allowed on each readback.

Open question Establish an in-state physical bound on between-level behavior or restrict the conclusion to the measured settings.

Derivation and checks
Live reference under gain drift
In a separate affine dose example a live zero still allows a sign error. Two reference levels recover a positive local increment, 0.129–0.771 percentage points, with the 0.70-point cap still unresolved.
A narrower bracket can still fail
For the specified dose example, narrowing the reference bracket at readback error 0.08 gives an edge upper bound of 0.77781 percentage points against a 0.70-point limit. Reducing that error to 0.05 gives 0.65763 under the assumed curvature bound and exact applied inputs.
Finite calibration
A three-times continuously differentiable bump supported inside an unsampled interval preserves all sampled values. Its width can shrink while its curvature grows and the response stays monotone.
  1. Use the same three-level estimator for the live reference and its error bound.
  2. Extend the triangularly averaged result to points only with a bound on how rapidly curvature itself can change.
  3. Check an independent level or measure the relevant setting directly when that bound is unavailable.

The perturbation limits inference about curvature. Its amplitude is small as the support shrinks. The numerical margins describe stipulated detector models.

The contribution ties reference spacing, readback precision and model regularity to an explicit pass or unresolved decision.

Testable hypotheses

The first decision is whether the driven control can be reproduced without a discharge. The three outcome tests then apply separately to the same cassette.

A matched control is possible
At the same gas conditions, compare a driven state with no detectable discharge and a state with an independently confirmed inductive discharge. Qualify the electrical and thermal histories in both orders. A failed match leaves the incremental discharge contrast unresolved.
The discharge reduces particle load
For the first planned 495 eV comparison, measure incident flux, charged and neutral hydrogen, escape and first contacts across the face and edges. The hypothesis passes only if total benefit and local load limits pass together after accounting for unknown destinations.
The discharge reduces absorbed dose
Start with a steady proton beam near 177 MeV and compare dose in water per incident fluence, with independent beam position and water-equivalent thickness. Check edges and secondary particles separately. A center-only reduction leaves the wider shielding claim unresolved.
The discharge improves net dust clearance
Hold the external cleaning drive comparable, then track marked dust first contacts, net clearance, late return and nearby deposition. A higher clearance is useful only when return and near and far deposition remain within the stated limits.

Scope. A resolved benefit and qualified local limits would establish a result for the tested configuration. Transfer across energy, angle, timing or adjacent cassettes requires its own evidence.

References

  1. Erik Marten Klein, Patric Seefeldt, Maciej Sznajder & Thomas Renger · 2023. Interaction Study of Energetic Protons and Electrons with the Vacuum Ultra Violet Source used in the Complex Irradiation Facility

  2. A. M. Daltrini and colleagues · 2008. Plasma power measurement and hysteresis in the E-H transition of a rf inductively coupled plasma system

  3. R. Bamford and colleagues · 2008. The interaction of a flowing plasma with a dipole magnetic field: measurements and modelling of a diamagnetic cavity relevant to spacecraft protection

  4. Charles R. Buhler and colleagues · 2025. Electrodynamic Dust Shield on the Surface of the Moon

  5. Charles R. Buhler · 2004. Analysis of a Lunar Base Electrostatic Radiation Shield Concept

  6. Joint Committee for Guides in Metrology · 2008. Evaluation of measurement data — Guide to the expression of uncertainty in measurement

  7. Herbert J. Ryser · 1957. Combinatorial Properties of Matrices of Zeros and Ones

  8. Gustav Elfving · 1952. Optimum Allocation in Linear Regression Theory

  9. Natalia E. Papitashvili & Joseph H. King · 2020. OMNI 5-minute data

  10. George E. P. Box & Kenneth B. Wilson · 1951. On the Experimental Attainment of Optimum Conditions

  11. Carl de Boor · 2005. Divided Differences

  12. Hermann Fuchs and colleagues · 2021. Design and commissioning of a water phantom for proton dosimetry in magnetic fields

  13. Jinhai Sun and colleagues · 2023. Validation of inductively coupled plasma simulation model by laser Thomson scattering experiment

  14. J. M. de Regt, R. D. Tas, J. A. M. van der Mullen & D. C. Schram · 1996. A closed inductively coupled plasma for lighting purposes mapped by spectroscopical techniques

  15. Bernard Gottschalk, Ethan W. Cascio, Juliane Daartz & Miles S. Wagner · 2015. On the nuclear halo of a proton pencil beam stopping in water