Chapter I · Stan Schneider

Arctic Magnetic Core

When a magnetic joint releases, what can nearby field and motion measurements tell us about the source of the disturbance?

Concept illustration of a suspended flywheel beside a separate magnetic coupling.
Concept illustrationA suspended flywheel and a separate magnetic coupling illustrate the two systems considered in this study.Open full-size research figure

Overview

When a magnetic joint releases near a freely coasting rotor, a large change in the local field may come mostly from the moving magnet itself. In two reversible target models, the source accounts for 88.5–92.5% of the predicted mirror contrast at 5% residual holding force. The target contribution is about 17–35 nT across a 10 mm measurement baseline.

The first experiment would hold the target fixed and the rotor stopped. It would compare two mirrored withdrawals at the same measured holding force, then replay the measured positions of the source magnet with a nonmagnetic substitute in the same fixture. The small difference left after that replay is the quantity to test. The later studies ask how to separate magnetic and mechanical disturbances during release and during free coast with the suspension active.

Research status. The results below are analytical or numerical under stated assumptions. Published experiments establish their own precedents. The Arctic Magnetic Core fixture, its compatibility limits and its complete docking and release cycle await hardware validation.

Comparison with prior work

Previous missions have flown precision rotors, demonstrated magnetic capture and separated magnetic disturbances from other spacecraft signals. Here the question is how to identify the source of a disturbance when a magnetic joint sits near a free-coasting rotor. The comparisons specify where the published work ends and what the Arctic models add. Scientific priority remains open.

From mapping a magnetic head to isolating the target contribution

PUBLISHED STUDY

Kyle P. Doyle, Mason A. Peck & Erik E. Komendera · 2019

Doyle, Peck and Komendera mapped the field around an electropermanent docking head. Switching the magnets with a ferromagnetic target present produced a larger local field change in their trials than switching them with the target absent. [1]

Scope. These were field-mapping trials of a switching end effector with different contact and activation sequences.

ARCTIC MAGNETIC CORE

Extension and result

We compare two mirror retractions at the same modeled residual holding force and calculate a signed field-gradient projection at the neighboring rotor. A pose-matched nonmagnetic replay isolates the direct source term in the model.

Established in the model. At 5% residual holding force, the full contrast is 22.97–30.16 µT/m in two reversible material models. Subtracting the pose-matched source term leaves 1.72–3.46 µT/m, or about 17–35 nT across 10 mm.

At 5% residual holding, the modeled linear target accounts for 7.5% and the saturating target for 11.5% of the cross-gradient contrast.
Direct-source and target terms in the mirror contrastThe direct source accounts for 88.5–92.5% of the nominal contrast. The modeled target term is 1.72–3.46 µT/m, corresponding to about 17–35 nT across a 10 mm baseline.Open full-size research figure

Testable hypothesis. A stopped-rotor test can resolve the target term if the two physical holding forces are matched, the source positions are reproduced in the dummy and the expanded uncertainty of the double difference is at most 0.25 µT/m.

Recalculate the example

Take the full and source-only signed gradients for each modeled target at 5% residual holding. Use a 10 mm probe separation and report rounded field-equivalent values.

  1. Linear target: 22.97 − 21.25 = 1.72 µT/m
  2. Saturating target: 30.16 − 26.70 = 3.46 µT/m
  3. 1 µT/m × 0.010 m = 10 nT

Expected result. The residual is about 17 nT for the linear target and 35 nT for the saturating target. The predicted full contrast is about 230–302 nT at the same separation.

What a coast measurement actually measures

PUBLISHED STUDY

S. Buchman & J. P. Turneaure · 2011

Buchman and Turneaure analyzed spin-speed and other disturbances in the electrostatically suspended gyroscopes flown by Gravity Probe B. [2]

Scope. Their apparatus and disturbance sources belong to a precision relativity experiment with a different suspension and readout.

ARCTIC MAGNETIC CORE

Extension and result

We derived phase-dependent bounds for the endpoint and slope methods in the same hypothetical coast, giving a method check for the planned magnetic-suspension measurement.

Established in the model. In the 90-minute sinusoidal example the endpoint contribution vanishes to first order. The all-sample slope can imply 0.90 µW of apparent loss.

Testable hypothesis. Independent temperature calibration will explain a measurable portion of the difference between the two estimators in a paired thermal-cycle test.

Recalculate the example

Use E₀ = 10 J, Aₛ = 127.81 × 10⁻⁶ and a 5,400 s window equal to the thermal period.

  1. q = πW/P = π
  2. Endpoint bias = 4E₀Aₛ|sin π|/W = 0
  3. Fit bias = 12E₀Aₛ/(πW) ≈ 0.904 µW

Expected result. The difference follows from the choice of estimator at fixed modeled thermal conditions.

From magnetic injection to matched replay

PUBLISHED STUDY

M. Armano et al. · 2025

Armano and colleagues used controlled magnetic injections in flight to infer magnetic parameters of LISA Pathfinder test masses. [4]

Scope. Their test masses were free-falling precision references and the signals were from that apparatus.

ARCTIC MAGNETIC CORE

Extension and result

On a dock–rotor assembly we propose matching the field history at the rotor and independently reproducing the mechanical loads, with a check against actual docking.

Established in the model. A magnetic-only replay residual that appears above the random-error allowance can become unresolved once the replay mismatch is included.

Testable hypothesis. If the fixture reproduces the local field, gradients, timing and mechanical loads within their qualified uncertainties, the combined replay provides a test of the docking response over the chosen interval.

Recalculate the example

Use optical contrast values B = 0.47 µm and C = 0.60 µm, independent 0.04 µm standard uncertainties and a ±0.040 µm bound for replay mismatch.

  1. C − B = 0.13 µm
  2. 2√(0.04² + 0.04²) ≈ 0.113 µm
  3. 0.13 ± (0.113 + 0.040) µm → [−0.023, 0.283] µm

Expected result. The interval crosses zero. Under these assumptions the modeled residual cannot establish a separate mechanical contribution.

From demonstrated capture to an observable release

PUBLISHED STUDY

Jason Forshaw et al. (Astroscale) · 2022

The ELSA-d team reported repeated magnetic capture with a prepared target and release during its orbital demonstration. [6]

Scope. Those operations establish feasibility in the demonstrated configuration. Their published record does not supply the local contact loads or edge-by-edge motion for AMC.

ARCTIC MAGNETIC CORE

Extension and result

Our impact model separates local opening, center motion and eventual departure, and proposes independent measurements of each state.

Established in the model. A single edge can open at 16.5 mm/s while the module centers continue to approach at 4.18 mm/s in the modeled off-center event.

Testable hypothesis. In the specified tilted fixture, measured trajectories should allow local opening with continued center closing under conditions comparable to the model.

Recalculate the example

Use 30 mm/s initial approach, effective normal mass 4.00 kg, combined center reduced mass 7.20 kg and coefficient of restitution 0.55.

  1. J = (1 + 0.55) × 4.00 × 0.030 ≈ 0.186 N·s
  2. Local opening = 0.55 × 30 = 16.5 mm/s
  3. Signed center speed = −30 + 1000 × J/7.20 ≈ −4.17 mm/s using rounded inputs

Expected result. The signs differ. The full-precision geometry in the source calculation gives −4.18 mm/s for the center speed.

Research updates

Chapter I · Measuring interaction between a rotor and a magnetic dock

Rotor losses and disturbance attribution

A full thermal cycle can still bias a coast fit

First-order analytic model · sinusoidal temperatures

If the rotor expands and the speed readout drifts with temperature, a coast fit can report an apparent loss even when end-point readings span exactly one thermal period.

Gravity Probe B reported unexpected changes in spin and gyro readouts in orbit. A separate laboratory study by Siamaki and colleagues measured spin-down on a superconducting bearing. Both motivate treating speed metrology as part of the loss measurement. [2][3]

We derived separate phase-dependent thermal biases for two estimates applied to the same coast window. Matching the recorded temperatures at the ends removes the first-order endpoint term over one period. The fit over all readings can still be biased.

Bends=4E0AsW|sinq|
Bfit=12E0AsW|sinq−qcosq|q2

E₀ is the reference rotational energy, W is the fit window, q = πW/P and P is the shared thermal period. Aₛ is the amplitude of the combined fractional effect of rotor expansion and temperature-dependent speed calibration.

After 90 minutes the first-order endpoint bias is zero, while the linear-fit bias can be 0.90 microwatts.
Thermal drift in a spin-down estimateThe curves show the worst starting phase for each estimator in a model with a 90-minute temperature cycle.Open full-size research figure

Open question Measure the rotor temperature and speed-reference drift independently, then recompute both estimators on paired coast records.

Derivation and checks
Complete period
For a 10 J rotor and a 90-minute cycle with combined amplitude 127.81 parts per million, the modeled end-point bias is zero to first order. The slope fit reaches 0.90 µW.
Shorter window
For the same inputs and a 60-minute window, the maximum end-point and slope-fit biases are 1.23 and 1.86 µW, respectively.
  1. Expand the moment of inertia and the speed-readout scale to first order in their respective temperatures.
  2. Use a difference of sines for the end points and the time–signal covariance for the uniformly weighted fit.
  3. Maximize the absolute estimator bias over the unknown starting phase.

The expressions assume a common sinusoidal period and, for the fit, continuous uniform sampling. Real gaps, fit weights and thermal dependence of the physical losses require separate treatment.

The contribution is the quantitative comparison of the two coast estimators under the same explicit thermal inputs.

A docking residual depends on how well the magnetic replay matches

Control contrasts · synthetic uncertainty budget

The difference between a full dock and a magnetic replay cannot by itself identify a mechanical effect. A small mismatch between the two field histories can account for the residual.

LISA Pathfinder used in-flight magnetic excitations to infer properties of free-falling test masses. Wegrzyn and colleagues measured reaction-wheel braking in an imposed field. These experiments supply calibration precedents for different systems. [4][5]

We specify five records that separate baseline, magnetic response, mechanical response, combined response and transfer to the real maneuver on one assembly. Each comparison uses the same signed optical statistic and physical time window.

I=E−B−D+A,R=C−E

A is coast alone, B is magnetic replay, C is full docking, D is mechanical replay and E is the combined replay. I measures interaction under matched inputs. R tests transfer of the combined replay to docking.

The modeled docking-minus-replay contrast is 0.13 micrometres. Its expanded interval crosses zero when replay mismatch is included.
How replay mismatch changes the conclusionThe dashed interval includes the field-replay mismatch. This example quantifies what the replay must resolve before a residual can be attributed.Open full-size research figure

Open question Measure the magnetic and mechanical inputs independently and verify replay equivalence before interpreting the optical residual.

Derivation and checks
Readout errors only
With B = 0.47 µm, C = 0.60 µm and independent standard uncertainties of 0.04 µm, C − B = 0.13 µm. Twice the standard uncertainty of the difference gives 0.017 to 0.243 µm.
Add a bounded mismatch
Adding a ±0.040 µm calibration allowance gives −0.023 to 0.283 µm. In this example the residual is no longer resolved.
  1. Subtract the two replay records from the combined replay and restore the common baseline.
  2. Compare full docking with the combined replay separately.
  3. For the illustrative magnetic-only comparison, propagate the random errors of B and C and add the bounded mismatch arithmetically.

A replay match requires the relevant local field components, gradients and timing, as well as checks for injection hardware and fixture motion. The example does not estimate an actual confidence interval for the device.

The proposed contribution is a bounded compatibility measurement on one reconfigurable dock–rotor assembly. The uncertainty example identifies a condition that can make that measurement inconclusive.

Magnetic coupling and release

The mirror contrast is dominated by motion of the source

Finite-source calculation · two reversible target laws · proposed bench test

At equal modeled holding force the mirror contrast is observable in the model. Most of it is reproduced by evaluating the source magnet at the same modeled poses with the target response omitted.

Laboratory field maps of docking heads show that target presence and the order of switching matter. In-flight injections on LISA Pathfinder provide a precedent for separating magnetic parameters with controlled inputs. [1][4]

We calculate the residual of a two-condition comparison after subtracting a pose-matched comparison on a nonmagnetic substitute. The observable is the signed cross-gradient projected along the actual mirror motion.

Dtarget=Dfull−Ddummy

D is the signed difference between the two retractions for the preselected gradient projection. Full denotes the magnetic target and dummy denotes the source replay with a nonmagnetic substitute.

Open question Measure the full contrast and double difference on the installed fixture. Require the 95% interval for the force difference to lie within ±0.5 mN or interpolate both paths to a common measured force with propagated uncertainty.

Derivation and checks
Modeled target response
The two models leave residuals of 1.72 and 3.46 µT/m. The source accounts for 92.5% and 88.5%, respectively.
Sensitivity to placement
A modeled 0.10 mm trajectory mismatch can contribute up to 0.102 µT/m. A modeled 0.20 mm reference relocation can contribute up to 0.085 µT/m. Both put pressure on the 0.25 µT/m uncertainty budget.
Separate experimental gates
For the full contrast, the proposed expanded uncertainty is at most 2 µT/m. For the double difference it is at most 0.25 µT/m, equivalent to 2.5 nT over 10 mm.
  1. Match axial holding force for the two mirror paths in the model.
  2. Evaluate the prescribed gradient projection at the same rotor reference for both paths.
  3. Replay the same source poses with the nonmagnetic substitute and subtract its mirror contrast.
  4. Compare the residual with the combined uncertainty of the proposed paired measurement.

Material shape, remanence, source back-reaction and fixture motion can affect this residual. A laboratory attribution requires a verified source replay and a separate measurement of the background field.

The values are model predictions for the specified geometry and reversible response laws. The first bench experiment would test the signed residual rather than any claim about simultaneous operation.

An opening edge can coexist with closing centers

Numerical rigid-body contact example · single frictionless impact

The first contact happens at a point on the interface. Rotation changes that point's speed, so the direction of motion at the edge can differ from the direction of motion of the module centers after impact.

The ELSA-d team demonstrated on-orbit magnetic capture of a prepared client. Ruspini and Khatib described established local rigid-body contact dynamics. The local first-contact speed requires both translation and rotation at the contact point. [6][7]

We calculated signed local and center velocities for the same first impact, then used the result to distinguish first opening, possible recontact, soft capture, lock and sustained departure as separate observables.

u=n·[(vB+ωB×rB)−(vA+ωA×rA)]

n is the opening normal, v is center velocity, ω is angular velocity and r points from each center of mass to its contact point. Positive u indicates opening.

A five-degree tilt closes the gap at the rim while 8.72 millimetres remain at the center. At the same center closing speed, opposite rotations give modeled edge speeds of 16.1 and 43.9 millimetres per second.
First contact at an edgeA schematic for the selected rigid-body geometry. Edge arrival depends on both the closing speed and the sign of relative rotation.Open full-size research figure

Open question Track relative pose, several local gaps and the contact and latch signals on the same clock, then verify sustained departure against a defined boundary.

Derivation and checks
Same center approach
At 30 mm/s center approach, opposite angular rates in the modeled tilted interface give first-contact speeds of 16.09 and 43.91 mm/s.
Opposite signs after contact
With zero initial rotation in the off-center example, the first edge opens at 16.50 mm/s while the centers still approach at 4.18 mm/s.
  1. Evaluate local normal motion using the center velocity and the angular contribution at the first contact point.
  2. Calculate the single normal impulse using the effective mass and the stipulated coefficient of restitution.
  3. Apply that impulse to both translations and rotations, then compare the signed directions.

Multiple contacts, friction, compliant guides and a finite actuator impulse are outside the impact example. A one-dimensional energy barrier only describes its stipulated separation path.

The signed reversal provides a concrete case where an edge camera alone and a center tracker alone support different conclusions about release.

A withdrawal can increase the rotor-side field

Prescribed finite-source field model · numerical refinement and axial comparison

In the modeled release route, withdrawing the magnet reduced the source-field magnitude at a target-side point while increasing both the field and the gradient norm at the rotor location. The two locations respond to different parts of the trajectory.

Magnetic capture and release have flight precedent. Magnetic metrology on LISA Pathfinder shows why a field estimated at the test body has a different meaning from a sensor reading elsewhere. [4][6]

We applied the field calculation along the same approach, lock, withdrawal and departure sequence. Keeping the rotor reference point fixed exposes a transient that a target-side measurement or the locked endpoint alone would miss.

ΔB(r,t)=B(r,t)−B(r,t0),Gij=∂Bi∂xj

r is the fixed observation position and t₀ is the initial separated state. G is the local spatial field-gradient tensor. The Frobenius norm of a tensor change is computed from component differences.

The model shows the local field difference and gradient norm increasing when the release magnet is retracted.
Modeled field and gradient at the rotorThe traces are evaluated at one fixed rotor point in the quasistatic model. Ambient and spacecraft equipment fields are excluded.Open full-size research figure

Open question Measure the vector, gradient, force and torque at the corresponding phases on the same mounted assembly.

Derivation and checks
Lock to withdrawal
The rotor-side source-field magnitude increases from approximately 8.84 to 10.16 µT, while the target-side magnitude decreases from approximately 952 to 459 µT. The rotor-side gradient norm increases from approximately 111 to 137 µT/m.
Numerical checks
For 40 sensor–event combinations, doubled quadrature resolution and halved derivative step change the vector and tensor results by at most 0.019% and 0.032%, respectively.
  1. Evaluate both finite sources and the assumed induced target term at each recorded geometry.
  2. Compute the gradient from central differences and compare the initial, locked and withdrawn fields at the same rotor point.
  3. Refine the integration and derivative step and compare the axial evaluation with the closed form for a cylinder.

The route, source properties and target response are model inputs. Local field amplitude is not a measurement of holding force. The direction of the rotor-side change may reverse in a different geometry.

This example predicts a measurable difference between two locations through a single release route, subject to the assumptions of the field model.

What the instruments can resolve

One load line cannot separate lateral force from bending

Exact design-matrix rank result · synthetic held-out calibration

A lateral load applied at one known lever arm always brings the same proportional bending moment. Repeating that calibration can reduce random noise while preserving the ambiguity in its physical coefficients.

Kebede and colleagues calibrated an installed multi-axis force–moment sensor with separately applied forces and moments. The method motivates independent loading as a check of transfer in the AMC fixture. [8]

We constructed two response laws that are identical at one lever arm and diverge when tested at another, then compared how static calibration schemes transfer to held-out pure and mixed loads.

My=hFx,ceff=cx+hκy

h is the lever arm, Fₓ is lateral force, Mᵧ is bending moment, cₓ and κᵧ are the two cross-sensitivities.

Two model laws agree when tested at the original lever arm and differ when tested with pure bending couples or other load geometries.
Transfer of an axial force calibrationBars show the 95th percentile of the maximum transfer error in repeated synthetic tests with 0.030 mN window noise.Open full-size research figure

Open question Check the installed sensor with independent bending couples or widely spaced load lines and held-out mixed loads.

Derivation and checks
Exact ambiguity
The six-column example has rank four at a single 12 mm arm. The two laws give the same measured trace there and differ by 0.144 mN in a paired contrast at a new arm or under pure bending.
Held-out transfer
At 0.030 mN synthetic window noise, the modeled 95th percentile of the maximum held-out error with independent bending couples is 0.051 mN before including noise in the held-out records. A narrow two-arm design at 10 and 14 mm gives 0.198 mN.
  1. Write the moments produced by the lateral forces at a fixed arm as linear combinations of those forces.
  2. Compare two coefficient sets giving the same effective sensitivity at 12 mm.
  3. Estimate each calibration model on its own training loads and assess transfer on distinct loading combinations.

Full rank alone gives no guarantee of adequate accuracy. The simulation assumes known reference loads, a specified readout noise model and a static fixture. Dynamic transfer requires its own evidence.

The exact counterexample shows why passing a repeat calibration at its original arm does not establish load transfer.

Two field waveforms can give exactly the same telemetry

Exact sampling counterexample · floating-point reproduction

In the specified boxcar-and-sampling model, a 0.10 nT tone at 20 Hz and a 0.40 nT tone at 80 Hz produce identical 100 Hz records. Their physical amplitudes are on opposite sides of the example 0.25 nT decision threshold.

Flight magnetometers such as MAVEN distinguish loss of temporal bandwidth during downsampling from later lossless compression of the retained samples. [9]

We constructed an exact ambiguity across a physical threshold and calculated what an independently calibrated, faster raw record would see before the reduction.

H(f)=sin(πfT)πfT

f is input frequency and T is the width of the averaging window about each sample time.

A 20-hertz field peaking at 0.10 nanotesla and an 80-hertz field peaking at 0.40 nanotesla both produce a downlink amplitude near 0.09355 nanotesla.
One downlink record for two fieldsThe two synthetic inputs give identical averaged 100 Hz samples for the specified measurement aperture and input phases.Open full-size research figure

Open question Verify the analog bandwidth, stopband and timestamps using an independent reference and preserve native samples over the event.

Derivation and checks
Common downlink
At 100 Hz with centered 10 ms windows, both tones have recorded amplitude 0.09355 nT. The maximum computed sample difference over four seconds is 2.74 × 10⁻¹⁴ nT, consistent with floating-point rounding.
Faster reference
With 2.5 ms raw windows at 400 Hz the computed amplitudes are 0.09959 and 0.37420 nT. An actual reference also needs adequate analog bandwidth, calibration and noise performance.
  1. Integrate each cosine over the centered boxcar.
  2. On the grid n/100 s, the 20 Hz and 80 Hz cosine sequences coincide because 80 = 100 − 20.
  3. At T = 0.010 s the two boxcar gains have a ratio of four, which offsets the ratio of incident amplitudes.

The exact equality concerns the stated measurement operator and phases. It is a constructive non-identifiability result for that operator. The actual telemetry chain must be measured.

The counterexample connects a standard sampling identity to a concrete change in the inferred field-threshold decision.

Five passing frequencies can miss a failing stopband

Analytic interpolation bound · synthetic resonant counterexample

A narrow resonance can lie between frequency probes. Claiming a bound over the whole band requires information about the behavior between the samples.

The MMS search-coil instrument paper reports calibrated magnetic-field response for a flight sensor. It provides a relevant example of measuring transfer rather than inferring it from the output cadence. [10]

We constructed a stable response in which all five calibration points meet the allowance and an inter-probe resonance fails it. We also derived the result of adding a verified inter-probe derivative bound.

max(|H^i|+ui)+LΔf2≤0.125

Ĥᵢ is the estimated gain at probe i, uᵢ is an upper error allowance valid across the probe set, L bounds the transfer derivative between probes and Δf is the maximum probe spacing. A 0.05 nT residual allowance over a 0.40 nT input gives 0.125.

The largest of five tested values is 0.0067 nanotesla. The modeled peak between them reaches 0.080 nanotesla, above a 0.05 nanotesla allowance.
A narrow response between the test frequenciesThe synthetic resonance is centered at 217.4 Hz. The coarse test grid alone gives no bound on this inter-sample peak.Open full-size research figure

Open question Measure the complete differential acquisition chain across the required operating states and establish a defensible bound between the probes.

Derivation and checks
Hidden failure
The five probes from 200 to 240 Hz at 10 Hz intervals give residuals at or below 0.006705 nT. The constructed 217.4 Hz peak reaches 0.080 nT against a 0.05 nT allowance.
Folding
Under 100 Hz sampling the hidden resonance appears at 17.4 Hz. Detecting the physical input at 217.4 Hz calls for a reference with sufficient bandwidth.
  1. Evaluate the specified stable narrowband response at the five probes and at its resonant frequency.
  2. For a frequency between adjacent probes, use the nearest probe at distance no greater than half the spacing.
  3. Add the worst derivative contribution and the simultaneous probe-error allowance to the largest qualified probe value.

The sufficient condition assumes linear transfer and a verified derivative bound. A model of an isolated resonance does not establish those assumptions for a physical chain with other modes or saturation.

The numerical example makes an untested stopband peak large enough to reverse the compliance decision.

The peak bound depends on what is known about the phase

Conditional invariant bound · one damped mode

Identical single-event amplitudes can produce different peak guarantees when events repeat. The bound depends on residual motion, verified decay and whether the next excitation has a known achievable phase.

Singer and Seering demonstrated command shaping as a way to reduce residual vibration. We use the familiar phase idea to ask for a worst-case, per-event bound with an uncertain measured optical phase. [11]

We compared an arbitrary-phase invariant with a finite-error phase reference. This sets a condition on each modeled event rather than relying on cancellation averaged across many events.

ρC+Jmax≤C,ρ=e−T/τ
r2+J2−2rJcosε

C is the peak allowed previously, T the interval, τ the longest assumed decay time and J the event jump amplitude. r is the measured pre-event amplitude and ε bounds the directional error about the phase opposite that measurement.

The modeled upper bound starts near 0.041 micrometres with a tight phase bound and rises toward the uncontrolled bound near 0.069 micrometres.
Bound on the accumulated responseThe example assumes 0.5 s between pulses. The two curves show how uncertainty in relative phase changes the bound for this model.Open full-size research figure

Open question On the actual fixture, measure modal decay and phase transfer from independent optical and load records, then test the peak envelope in a held-out sequence.

Derivation and checks
Verified phase example
At a 0.50 s spacing and at most 20° phase error, the modeled peak is bounded by 0.0410 µm under the stated readout, decay and event amplitude bounds.
Arbitrary phase example
For the same spacing with unknown phase the bound is 0.06874 µm, above the example 0.050 µm allowance. The passive spacing calculated from the sufficient invariant is at least 1.482 s under these assumptions.
  1. Propagate the previous upper bound C through the decay interval.
  2. Use the triangle inequality for arbitrary phase. For a known error bound, use the cosine rule and add the observation error.
  3. Maximize the latter over the allowed pre-event amplitudes and event jumps. Convexity puts the maximum in the finite set of corner cases.

The result concerns one damped mode with an instantaneous jump. Finite excitations, other modes and the ability to deliver the desired phase within the docking trajectory need independent checks.

The project result links a conditional recurrent bound to phase and readout accuracy that can be checked independently.

A small near reading can hide cancellation

Constructed ambiguity · conditional spacing model

A small displacement near the dock can reflect genuinely weak forcing or cancellation between magnetic and mechanical contributions. If the magnetic term decreases with spacing, the two explanations predict different behavior farther away.

RINGS aboard the ISS provided a precedent for analyzing magnetic interaction between two controlled vehicles. That test system motivates checking the transfer with separation and phase on the actual geometry. [11][12]

We built two models with the same near reading and combined them with the arbitrary-phase single-event bound. Separate replays at two configurations can discriminate the two physical explanations.

|Jmech|+|Jmag|≤C(1−e−T/τ)

J with subscripts mech and mag denotes the mechanical and magnetic amplitudes in the optical mode. C is the modeled peak allowance, T is the interval and τ is the decay time.

As source-to-rotor separation increases, the curves for the total response differ according to the assumed mechanical contribution and the loss of cancellation.
Separation and a remaining mechanical responseThe model compares an arbitrary-phase sum, a cancellation scenario and the remaining mechanical term. The apparent minimum is conditional on the assumed mechanical and magnetic amplitudes.Open full-size research figure

Open question Qualify magnetic-only, mechanical-only and combined replays at two spacings, including independent optical quadratures and local field gradients.

Derivation and checks
Same near observation
Both constructions give 0.004 µm at 365 mm. In the cancellation case the two terms are +0.032 and −0.028 µm.
Different farther predictions
With the stipulated cubic magnetic falloff, the cancellation case grows to 0.02382 µm at 550 mm. The purely mechanical example remains at 0.004 µm. The arbitrary-phase single-event allowance for the stated repetition model is 0.01826 µm.
  1. Form two signed sums that reproduce the same measured near value.
  2. Keep the illustrative mechanical term fixed and scale only the magnetic term with distance.
  3. Compare the farther prediction with the single-event allowance implied by the phase-agnostic inequality.

The falloff and constant mechanical contribution are scenario assumptions. The measured fixture can have a spacing-dependent mechanical response and a different local magnetic scaling.

The counterexample shows why one small reading cannot select between the proposed operating modes.

Unknown fixture acceleration can hide early trajectory differences

Gaussian two-hypothesis calculation · synthetic pre-contact trajectories

Two mirror trajectories become distinguishable early in a specified model when fixture acceleration is known. If that acceleration is free to vary, much of the early signature can be absorbed by the fixture motion.

Scharf and Friedlander derived detection methods that separate signal and interference subspaces. Yang and colleagues measured docking kinematics on an air-bearing platform. These are methodological and experimental precedents for separate parts of the AMC test. [13][14]

We quantified how simulated pre-contact classification changes when the same lateral position and angle records must also explain an unknown background acceleration.

Perr=Φ(−d2)

d is the norm of the trajectory difference after whitening by the assumed noise covariance and projecting out nuisance terms. Φ is the standard normal cumulative distribution.

With initial position and velocity uncertain, some modeled branches separate before contact. Unknown acceleration makes most early differences harder to resolve.
What can be distinguished before contactThe dashed line marks the illustrative 5% error threshold for this observability calculation.Open full-size research figure

Open question Measure the fixture motion independently, verify the covariance on repeated launches and test the discrimination on held-out records before first contact.

Derivation and checks
Known fixture acceleration
At correlation 0.6 in the specified noise model, the joint lateral and angle record reaches the 5% model-error criterion in 0.35 s for the mirror pair and 0.60 s for the separate torque and lateral-force contrasts.
Unknown constant fixture acceleration
At 1.10 s the calculated errors are 9.80% for the mirror pair, 36.08% for the torque contrast and 32.65% for the lateral-force contrast. The weak magnetic-memory contrast remains near chance.
  1. Whiten each model trajectory difference using the specified autoregressive covariance.
  2. Project away the unknown starting position and speed. In the second case also project away the constant-acceleration term.
  3. Combine the two assumed independent optical channels and compute the Gaussian error for the two simple hypotheses.

The inputs are modeled trajectories, assumed covariance and a particular contact geometry. Unknown model parameters and a measured optical covariance can change the result.

The example gives a numerical test of the role of the fixture reference in an early interpretation of the motion.

Testable hypotheses

The proposed tests start with a stopped rotor and a fixed target. A measured force match and an independent reference are prerequisites for attributing the field residual. Separate release and coast tests address what happens when the parts move.

Does the target contribution survive source replay?
With the target fixed and rotor stopped, pair the mirror runs at the same measured force and repeat the measured source poses with a nonmagnetic substitute. The prediction calls for a positive residual. A confidently opposite sign or a result confined to a prespecified small interval would narrow the claim. The proposed expanded uncertainty for attribution is at most 0.25 µT/m.
Can the dock–rotor interaction be isolated?
Compare matched coast, magnetic replay, mechanical replay, combined replay and real docking on one fixture at the same rotor state. If the independently measured inputs agree within the planned error budget, compare the interaction contrast and the docking-to-replay residual. Report the uncertainty or an upper bound when a contrast remains unresolved.
Does withdrawal increase the neighboring field in this geometry?
Measure the target-side field and load and the rotor-side vector and gradient from lock through withdrawal, with synchronized pose and an independent field reference. The modeled route predicts a rotor-side increase while the target-side field decreases. The signs and corresponding phase window can be rejected by a resolved measurement.
Does the force calibration transfer?
Apply independently referenced bending and mixed loads on an installed sensor at held-out lever arms. For the illustrated static test, require the simultaneous interval for corrected axial error to lie inside ±0.072 mN. A same-arm repeat does not qualify the transfer.
Can reduced telemetry support the field threshold?
Compare retained high-bandwidth and reduced records in blind in-band and out-of-band tests with a calibrated source. Reject the reduced record as a basis for the threshold if the qualified residuals can reverse the verdict. A bound between frequency probes must be independently supported.
Can the trajectory be identified before contact?
Check paired mirror releases with joint optical measurements and an independently measured fixture acceleration. Use a held-out early window and an error criterion set before examining the test data. If the background dominates the signature, retain the early record as diagnostic evidence only.

Scope. The thresholds below belong to the stated models and proposed tests. A physical result would apply to the measured fixture and conditions.

References

  1. Kyle P. Doyle, Mason A. Peck & Erik E. Komendera · 2019. Safe, Failure-Tolerant CubeSat Docking Using Passive Magnetic Mechanisms

  2. S. Buchman & J. P. Turneaure · 2011. The effects of patch-potentials on the gravity probe B gyroscopes

  3. Mohammad Siamaki et al. · 2022. Design, Build, and Evaluation of an AC Loss Measurement Rig for High-Speed Superconducting Bearings

  4. M. Armano et al. · 2025. Precision measurements of the magnetic parameters of LISA Pathfinder test masses

  5. Emilia Wegrzyn et al. · 2020. Eddy Current Effects in Spacecraft Mechanisms

  6. Jason Forshaw et al. (Astroscale) · 2022. ELSA-d: Mission Demonstration Summary

  7. Diego Ruspini & Oussama Khatib · 2000. A Framework for Multi-Contact Multi-Body Dynamic Simulation and Haptic Display

  8. Getnet Ayele Kebede et al. · 2019. Decoupled Six-Axis Force–Moment Sensor with a Novel Strain Gauge Arrangement and Error Reduction Techniques

  9. J. E. P. Connerney et al. · 2015. The MAVEN Magnetic Field Investigation

  10. O. Le Contel et al. · 2016. The Search-Coil Magnetometer for MMS

  11. Neil C. Singer & Warren P. Seering · 1990. Preshaping Command Inputs to Reduce System Vibration

  12. Bruno Alvisio · 2015. Development and validation of an Electromagnetic Formation Flight simulation as a platform for control algorithm design

  13. Louis L. Scharf & Benjamin Friedlander · 1994. Matched subspace detectors

  14. Xiaoze Yang et al. · 2025. Analysis and Experiments of an Electromagnetic Docking Mechanism for Repeated Docking and Separation of the CubeSats